The Device Readings report brings consumption readings aggregated per device, ready for periodic analysis and reporting.
Some columns are optional and only appear depending on your account's configuration — if a column listed below isn't present in your file, it isn't enabled for your organization.
Columns
| Column | Description |
|---|---|
| device_id | Device identifier |
| channel | Device channel (only present for accounts with multi-channel devices) |
| city | Device's city |
| remote_id | Device's remote identifier |
| reading | Converted reading, in m³ |
| raw_pulses_delta | Raw pulse variation since the previous reading |
| reading_date | Reading date and time |
| reading_time | Device communication/send date and time |
| latency_min / latency_max | Communication latency range |
| records | Number of raw records aggregated into this row |
| multiplier | Multiplier factor used in the reading calculation |
| raw_pulses | Raw pulses read |
| discount_offset / result_offset | Offsets used in the reading calculation |
| battery / battery_source | Battery level and its source (optional) |
| device_name | Device name (optional) |
Along with this report, an alarms table for the period is also exported, with: device, channel, city, name, alarm type, code, date, and criticality.
Example
| device_id | channel | city | remote_id | reading | raw_pulses_delta | reading_date | reading_time | latency_min | latency_max | records | multiplier | raw_pulses | discount_offset | result_offset | battery | battery_source | device_name |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 128432 | 0 | Curitiba | RM-004521 | 152.100 | 10 | 2025-06-02 00:00:00 | 2025-06-02 00:02:05 | 40 | 98 | 4 | 1 | 152100 | 0 | 0 | 88 | device | Water meter, Rua das Palmeiras 45 |
| 128432 | 0 | Curitiba | RM-004521 | 152.150 | 5 | 2025-06-02 01:00:00 | 2025-06-02 01:02:11 | 42 | 101 | 4 | 1 | 152150 | 0 | 0 | 88 | device | Water meter, Rua das Palmeiras 45 |
| 128432 | 0 | Curitiba | RM-004521 | 152.230 | 8 | 2025-06-02 02:00:00 | 2025-06-02 02:01:58 | 39 | 95 | 4 | 1 | 152230 | 0 | 0 | 87 | device | Water meter, Rua das Palmeiras 45 |
| 128432 | 0 | Curitiba | RM-004521 | 152.340 | 11 | 2025-06-02 03:00:00 | 2025-06-02 03:02:14 | 45 | 134 | 4 | 1 | 152340 | 0 | 0 | 87 | device | Water meter, Rua das Palmeiras 45 |
| 128432 | 0 | Curitiba | RM-004521 | 152.410 | 7 | 2025-06-02 04:00:00 | 2025-06-02 04:01:49 | 41 | 99 | 4 | 1 | 152410 | 0 | 0 | 86 | device | Water meter, Rua das Palmeiras 45 |